bdbg-09
Detecting unit of gamma radiation
Certificates
  In Ukraine:
Pattern Approval Certificate of Measuring Instruments # UA-MI/1-1717-2005
of September 15, 2005 (Ó2071-05 number in the State Register for Measuring Instruments)
Hygienic conclusion of the State Sanitary-Hygienic Expertise # 05.03.02-04/22565
of May 24 2005 ÒÓ Ó 33.2-22362867-009-2004 approved by SCNR of Ukraine
(3Í rank for APP)
Photo
Purpose of use
Measurement of ambient equivalent dose rate (EDR) of gamma radiation.
Application
The detecting unit can be used both within data panels and automated systems of radiation monitoring.
Features
Data exchange between the detecting unit and the data display system through RS-485 interface.
Constant self-testing.
Availability of the statistical accuracy of measurement.
Ingress protection rating – ²Ð67.
Average service life of the detecting unit - not less than 10 years.
Specifications
- Measurement range of ambient equivalent dose rate of gamma radiation and basic relative error 0.05 µSv/h…10 Sv/h ±15%
(0.05 µSv/h…100 Sv/h - on demand)
Energy range of detected gamma and X-ray radiation and energy dependence MeV 0.05…3.0;
(0.05…1.25; ±25 %)
Integration time seconds 2…420
Time of operating mode setting of the detecting unit min 3
Operating supply voltage of the detecting unit from external power supply V 5(7-13)
Current consumption of the detecting unit for the entire gamma radiation EDR measurement range, not more than mA 30
Operating temperature range °Ñ -40…+60
Weight of the detecting unit without fastening elements kg 0.5
Dimensions of the detecting unit without fastening elements mm 170×60×60
Delivery kit
-
-
-
-




-

-
-
BDBG-09 detecting unit of gamma radiation;
corbel for vertical mounting of the unit;
cable connector;
technological kit for testing of the detecting units (one kit per one consignment of the detecting units), including:
- serial port adapter with power supply unit for PC connection;
- technological cables (2 pcs.);
- technological software CD (1 pc.);
technical description and operating manual (one copy per one consignment of the detecting units);
logbook;
cardboard box.