dosimeter - radiometer RKS-01 dosimeter - radiometer RKS-01
Gamma, beta radiation radiometer-dosimeter RKS-01
-   Gamma and X-ray radiation equivalent dose rate: 0.1…999.9 µSv/h
- Beta-particles flux density: 5…100 000 1/(cm²·min)
- Energy range:
-   gamma and X-ray radiation: 0.05…3.0 MeV
- beta radiation: 0.5…3.0 MeV
- Battery life: 2 500 hours
- Operating temperature range: -20…+50 °C
- Weight: 0.35 kg
- Dimensions: 220×80×35 mm
more...
dosimeter - radiometer MKS-05 dosimeter - radiometer MKS-05
Dosimeter-radiometer MKS-05
-   Gamma and X-ray radiation equivalent dose rate: 0.1…9 999 µSv/h
- Gamma and X-ray radiation equivalent dose: 0.001…9 999 mSv
- Beta-particles flux density: 10…100 000
1/(cm²·min)
- Energy range:
-   gamma and X-ray radiation: 0.05…3.0 MeV
- beta radiation: 0.5…3.0 MeV
- Battery life: 2 000 hours
- Operating temperature range: -20…+50 °C
- Weight: 0.15 kg
- Dimensions: 12×52×26 mm
more...
DKS-02PN CADMIUM search alarm dosimeter DKS-02PN CADMIUM search alarm dosimeter
DKS-02PN "CADMIUM" search alarm dosimeter
-   Measurement range of photon radiation equivalent dose rate (EDR): 0,01…100,00 µSv/h
- Energy range of detected photon-ionizing radiation: 0,033 - 3,00 Mev
- Energy range of detected neutron radiation: from thermal to 14,00 Mev;
- Battery life: 65 hour
- Operating temperature range: -20…+50 °C
- Weight of the control panel, not more than: 0,35 kg
- Dimensions: 100×83×36 mm
more...
gamma radiation dosimeter - DKS-02P gamma radiation dosimeter - DKS-02P
Personal gamma radiation dosimeter with search function DKS-02P
-   Gamma and X-ray radiation equivalent dose rate:
0.05…300.0 µSv/h
- Maximal measurement time: 2 seconds
- Energy range gamma and X-ray radiation: 0.05…3.0 MeV
- Battery life: 100 hours
- Operating temperature range: -10…+40 °C
- Weight: 0.25 kg
- Dimensions: 127×72×35 mm
more...
gamma, beta radiation dosimeter - radiometer MKS-07 gamma, beta radiation dosimeter - radiometer MKS-07
Search gamma, beta radiation dosimeter-radiometer MKS-07
-   Gamma and X-ray radiation equivalent dose rate:
0.1 µSv/h … 2.0 Sv/h
- Gamma and X-ray radiation equivalent dose :
1.0 µSv … 9 999 mSv
- Beta-particles flux density: 5…100 000
1/(cm²·min)
- Energy range:
-   gamma and X-ray radiation: 0.05…3.0 MeV
- beta radiation: 0.15…3.0 MeV
- Battery life: 100 hours
- Operating temperature range: -25…+55 °C
- Weight: 4.2 kg (complete set in packing)
- Complete set dimensions: 445×255×85 mm

more...
radiation dosimeter - radiometer MKS-U radiation dosimeter - radiometer MKS-U
Multipurpose dosimeter-radiometer
-   Equivalent dose rate measurement range:
-   with combined detector:
0.1…10 000 000 µSv/h
- with external detector:
0.01…100 Sv/h
- Gamma and X-ray radiation equivalent dose:
0.001 … 9 999 mSv
- Beta-particles flux density: 10…200 000
1/(cm²·min)
- Energy range:
-   gamma and X-ray radiation: 0.05…3.0 MeV
- beta radiation: 0.3…3.0 MeV
- Battery life: 100 hours
- Operating temperature range: -40…+50 °C
- Weight: 8.0 kg (complete set in packing)
- Complete set dimensions: 490×255×130 mm

more...
radiation dosimeter - radiometer MKS-U radiation dosimeter - radiometer MKS-U
Multipurpose dosimeter-radiometer (for Fire Safety Professionals)
-   Equivalent dose rate measurement range with combined detector:
0.1…10 000 000 µSv/h
- Gamma and X-ray radiation equivalent dose:
0.001…9 999 mSv
- Beta-particles flux density: 10…200 000
1/(cm²·min)
- Energy range:
-   gamma and X-ray radiation: 0.05…3.0 MeV
- beta radiation: 0.3…3.0 MeV
- Battery life: 100 hours
- Operating temperature range: -40…+50 °C
- Weight: 8.0 kg (complete set in packing)
- Complete set dimensions: 490×255×130 mm

more...
gamma radiation dosimeter - radiometer DKG-21 gamma radiation dosimeter - radiometer DKG-21
Personal gamma radiation dosimeter
DKG-21
-   Gamma and X-ray radiation equivalent dose rate: 0.1…1 000 000 µSv/h
- Gamma and X-ray radiation equivalent dose: 0.001…9 999 mSv
- Energy range gamma and X-ray radiation: 0.05…6.0 MeV
- Recording discreteness of dose accumulation history into non-volatile memory during working shifts (8 hours): 5…30 min.
- Time of data storage in non-volatile memory, not less than 10 years
- Speed of data exchange through infrared port:
38 400 bit/s
- Battery life: 2 200 hours
- Operating temperature range: -10…+50 °C
- Weight: 0.08 kg
- Dimensions: 86×54×9 mm
more...
Automated system of personal dosimetry control Automated system of personal dosimetry control
Automated system of personal dosimetry control
-   ASPDC-21 is purposed for personal equivalent dose HP(10) measurement, for gamma radiation equivalent dose rate HP(10) measurement and automated data base of dose accumulation by the personnel.
- ASPDC-21 may be used at atomic power engineering sites, at enterprises and organizations that deal with gamma radioactive sources.
- System peculiarities see here
more...
gamma radiation dosimeter - radiometer gamma radiation dosimeter - radiometer
Detecting unit of gamma radiation
-   Gamma radiation equivalent dose rate:
0.1…10 000 000 µSv/h (up to 100 Sv/h at request)
- Energy range gamma radiation: 0.05…3.0 MeV
- Integration time: 2…420 seconds
- Operating temperature range: -40…+60 °C
- Weight of the detecting unit without fastening elements: 0.5 kg
- Dimensions of the detecting unit without fastening elements: 170×60×60 mm
more...
gamma radiation dosimeter - radiometer gamma radiation dosimeter - radiometer
Detecting unit of neutron radiation
-   Measurement range of thermal neutron flux density: 10…105 N/(cm²·min)
- Measurement range of fast neutron flux density: 50…105 N/(cm²·min)
- Operating temperature range: -25…+55 °C
- Weight of the detecting unit with main moderator, not more than: 0.8 kg
- Dimensions of the detecting unit with main moderator, not more than: ø76×195 mm
more...
Detecting unit of alpha radiation Detecting unit of alpha radiation
Detecting unit of alpha radiation
- Measurement range of alpha-particles flux density: 0,1…105 1/(cm²·min)
- Mica thickness: 10-11 mkm
- Alpha-particles detection efficiency: 24-32 %
- Window area:21 cm²
- Operating temperature range: -25...+55 °C
- Weight of the detecting unit 0,65
- Dimensions of the detecting unit without the telescopic bar holder: ø105×56 mm
more...
radiation dosimeter - radiometer MKS-05 radiation dosimeter - radiometer MKS-05
Dosimeter-radiometer MKS-05 for everyday use
-   Gamma radiation equivalent dose rate:
0.1…999.9 µSv/h
- Gamma radiation equivalent dose:
0.001…9 999 mSv/h
- Beta-particles flux density: 10…100 000
1/(cm²·min)
- Energy range:
-   gamma and X-ray radiation: 0.05…3.0 MeV
- beta radiation: 0.5…3.0 MeV
- Battery life: 6 000 hours
- Operating temperature range: -10…+50 °C
- Weight: 0.2 kg
- Dimensions: 120×52×26 mm
more...